CATAWBA COUNTY PERMIT DETAIL REPORT

BUILDING (R)
New Building
Lien Agent
STEWART TITLE GUARANTY COMPANY, 19 W HARGETT ST 507, RALEIGH NC 27601
Owner
BRANDY FORBES, 6445 VALWOOD RD, CONOVER NC 28613
Contractor

CONTACT LIST

GENERAL INFORMATION

CENSUS TRACT:

LOT#:

010201
4

LIEN AGENT ENTRY NUMBER:

PROPERTY ID#:

STREET ADDRESS:

6445 VALWOOD RD, CONOVER NC 28613

GIS

783456

PROJECT:

PROJECT DESCRIPTION:

New, one-story, single family dwelling, 3 bedrooms, 2 baths, attached garage no bonus room, unfinished basement

APPLIED:

EXPIRES:

ISSUED:

02/13/2018
02/13/2018
10/14/2021

STATUS:

Final

TOTAL # OF ROOMS:

NUMBER OF UNITS:

VALUE:

CODE EDITION:

ZONING:

# OF STORIES:

TYPE OF USE:

TOTAL SQ FT

 1
 4,823
$201,203 
 8
Single Fam. Res.
IRC 2012
1

RELATED_PERMIT#

WORK CLASS

STATUS

ISSUED

FINALED

ELER-05-2018-099116
New Building
Final
05/03/2018
07/19/2018
MECR-05-2018-099118
New Building
Final
05/03/2018
07/19/2018
MECR-05-2018-099759
New Building
Final
05/17/2018
07/17/2018
PLMR-03-2018-096092
New Building
Final
03/06/2018
07/17/2018

RELATED PERMITS

PLAN CASE

STATUS

COMPLETED

WORK CLASS

DISTURBED ACRES

Under Review
Building New

RELATED PLAN CASES

ACTIVITIES

DATE

ACTIVTY

COMMENTS

07/19/2018
Connect Perm. Power Main Service
Ok per Lamar
03/13/2018
Connect Temp. Saw Pole
Ok per Stephen email

INSPECTION HISTORY

SCHEDULED

COMPLETED

STATUS

INSPECTION TYPE

Building Final
Garry Cornell
07/19/2018
Approved
(828)217-0490
07/19/2018
Building Final
Garry Cornell
07/17/2018
Failed
(828)217-0490
07/17/2018
Image

CATAWBA COUNTY PERMIT DETAIL REPORT

Other Inspector Comments

Pipe off gutter drains a minimum of 6ft, install permanent support posts in basement, Sheetrock under stairwell, insulation needs to be put back in place in floor system, brace deck post

Rough Building
Garry Cornell
05/17/2018
Approved
(828)217-0490
05/17/2018
Insulation
Garry Cornell
05/17/2018
Failed
(828)217-0490
05/17/2018
Other Inspector Comments

History of inspections show that no in inspection for the prefabricated fireplace have been done . That inspection needs to be completed before covering with dry wall.

Rough Building
Garry Cornell
05/10/2018
Failed
(828)217-0490
05/10/2018
Other Inspector Comments

Repair for gable end truss doesn’t address the specifics for this situation, add OSB on sides of garage door before rescheduling

Rough Building
Garry Cornell
05/09/2018
Failed
(828)217-0490
05/09/2018
truss sheets on site

Provide repair drawings for cut gable end truss in garage area, add OSB to the sidewall of the garage door

Rough Building
Lamar Coffey
05/04/2018
Failed
(828)217-1105
05/04/2018
Other Inspector Comments

1. Install the required Windbracing to each side and above the garage door opening on the inside.

2. Provide the required TRUSS Drawings. 

3. Pending approvals of Rough Plumbing, Mechanical and Electrical

Outside Rough
Garry Cornell
04/26/2018
Approved
(828)217-0490
04/26/2018
Concrete Slab
Damon White
03/14/2018
Approved
(828)639-9742
03/14/2018
Note termite company
Terminix
Temp Saw Pole Connection
Stephen Winthrop
03/13/2018
Approved
(828)312-5726
03/13/2018
Concrete Slab
Stephen Winthrop
03/13/2018
Failed
(828)312-5726
03/13/2018
Other Inspector Comments
level rock in garage and install vapor barrier
Foundation
Jacob Justice
03/05/2018
Approved
(828)578-9498
03/05/2018
Concrete Wall
Damon White
02/27/2018
Approved
(828)639-9742
02/27/2018
GPS Data Capture
Ed Barton
02/20/2018
Approved
(828)312-2292
10/26/2020
Footing
Damon White
02/20/2018
Approved
(828)639-9742
02/20/2018
Other Inspector Comments
Setbacks ok
Building Final
Canceled
07/17/2018
E9 - rpermitdetail
Page 2 of 2