CATAWBA COUNTY PERMIT DETAIL REPORT

BUILDING (C)
Alteration
Architect
*RAY CAMPBELL DESIGN, 29 S COLLEGE AVE, NEWTON NC 28658
Contact Person
NEILL GRADING & CONSTRUCTION, , 
Land Owner
ASHFAR ENTERPRISES INC, 200 METROPLEX DR SUITE 275, EDISON NJ 08817-2606
Lien Agent
FIDELITY NATIONAL TITLE COMPANY, LLC, 223 S WEST ST SUITE 900, RALEIGH NC 27603
Owner
CATAWBA VALLEY MILLS, 3776 PLATEAU RD, NEWTON NC 28658-
Contractor

CONTACT LIST

GENERAL INFORMATION

CENSUS TRACT:

011802

LIEN AGENT ENTRY NUMBER:

PROPERTY ID#:

STREET ADDRESS:

3772 PLATEAU RD, NEWTON NC 28658

GIS

907882

PROJECT:

PROJECT DESCRIPTION:

Renovations to existing warehouse Facility, adding office space and toilets ***Temp Elec Only Agreement attached

APPLIED:

EXPIRES:

ISSUED:

08/24/2018
08/24/2018
12/18/2019

STATUS:

Final

TOTAL # OF ROOMS:

NUMBER OF UNITS:

VALUE:

CODE EDITION:

ZONING:

# OF STORIES:

TYPE OF USE:

TOTAL SQ FT

 1
 0
$446,000 
 0
Factory/Industrial
IBC 2012
1

RELATED_PERMIT#

WORK CLASS

STATUS

ISSUED

FINALED

ELEC-10-2018-106480
Alteration
Final
10/09/2018
01/07/2019
MECC-10-2018-106666
Alteration
Final
10/11/2018
01/03/2019
PLMC-09-2018-105863
Alteration
Final
09/24/2018
01/03/2019

RELATED PERMITS

PLAN CASE

STATUS

COMPLETED

WORK CLASS

DISTURBED ACRES

Approved
08/22/2018
Building Alteration
N/A

RELATED PLAN CASES

ACTIVITIES

DATE

ACTIVTY

COMMENTS

11/07/2018
Connect Temp. Power Main Service
Ok Per Brad

INSPECTION HISTORY

SCHEDULED

COMPLETED

STATUS

INSPECTION TYPE

Building Final
Craig Taylor
01/07/2019
Approved
(828)639-0396
01/07/2019
Other Inspector Comments
Final case
Image

CATAWBA COUNTY PERMIT DETAIL REPORT

Fire - Building Final
Kevin Head
01/07/2019
Approved
828-465-8239
01/07/2019
E911 address on building
Install address on street side of building.
Electrical items
Meet requirements for building code official.
Exit signage
Knock out the arrows pointing to the direction of nearest exit.
Fire Extinguishers
Mount as discussed, 5 total
Knox box required
Located between buildings.
Other corrections as noted
Label fire door that is not in use "NOT AN EXIT"
Fire - Building Final
Bruce Roseman
01/03/2019
Failed
01/03/2019
E911 address on building
Install address on street side of building.
Electrical items
Meet requirements for Building Code Official.
Exit signage

Knock out the arrows pointing to the direction of nearest EXIT.

Lower EXIT SIGN at loading dock door, below dock door drum.

Fire Extinguishers
Mount as discussed, 5 total.
Knox box required
Located between building.
Other corrections as noted
Label fire door that's not in use "NOT AN EXIT".
Building Final
Craig Taylor
01/03/2019
Failed
(828)639-0396
01/03/2019
Other Inspector Comments

1. Post 911 address 

2. Lower exit sign at loading dock. 

3. Install tactile signage at exits doors. 

4. Install the required fire extinguisher 

5. Knock out directional arrows to indicate travel path to exits. 

6. Install the required handicap gap bars. 

7. Restrooms walls  must have a nonadsordent surface

Framing Above Ceiling
Lamar Coffey
11/21/2018
Approved
(828)217-1105
11/21/2018
Rough Building
Garry Cornell
10/10/2018
Approved
(828)217-0490
10/10/2018
Concrete Slab
Stephen Winthrop
09/27/2018
Approved with notes
(828)312-5726
09/27/2018
Other Inspector Comments
bath area
E9 - rpermitdetail
Page 2 of 2